Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group - Université de Versailles Saint-Quentin-en-Yvelines
Journal Articles Arthritis & rheumatology Year : 2023

Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group

Silvia Sirotti
Fabio Becce
Luca Sconfienza
  • Function : Author
Lene Terslev
Esperanza Naredo
  • Function : Author
Pascal Zufferey
  • Function : Author
Carlos Pineda
Marwin Gutierrez
Antonella Adinolfi
  • Function : Author
Teodora Serban
  • Function : Author
Daryl Maccarter
  • Function : Author
Gael Mouterde
  • Function : Author
Anna Zanetti
  • Function : Author
Anna Scanu
  • Function : Author
Ingrid Möller
  • Function : Author
Ulrike Novo-Rivas
  • Function : Author
Raquel Largo
Piercarlo Sarzi-Puttini
  • Function : Author
Abhishek Abhishek
  • Function : Author
Hyon Choi
  • Function : Author
Nicola Dalbeth
Tristan Pascart
Sara Tedeschi
Annamaria Iagnocco
  • Function : Author
Helen Keen
Carlo Scirè
Georgios Filippou

Abstract

Objective To assess the reliability and diagnostic accuracy of new radiographic imaging definitions developed by an international multidisciplinary working group for identification of calcium pyrophosphate deposition (CPPD). Methods Patients with knee osteoarthritis scheduled for knee replacement were enrolled. Two radiologists and 2 rheumatologists twice assessed radiographic images for presence or absence of CPPD in menisci, hyaline cartilage, tendons, joint capsule, or synovial membrane, using the new definitions. In case of disagreement, a consensus decision was made and considered for the assessment of diagnostic performance. Histologic examination of postsurgical specimens under compensated polarized light microscopy was the reference standard. Prevalence‐adjusted bias‐adjusted kappa values were used to assess reliability, and diagnostic performance statistics were calculated. Results Sixty‐seven patients were enrolled for the reliability study. The interobserver reliability was substantial in most of the assessed structures when considering all 4 readers (κ range 0.59–0.90), substantial to almost perfect among radiologists (κ range 0.70–0.91), and moderate to almost perfect among rheumatologists (κ range 0.46–0.88). The intraobserver reliability was substantial to almost perfect for all the observers (κ range 0.70–1). Fifty‐one patients were included in the accuracy study. Radiography demonstrated an overall specificity of 92% for CPPD, but sensitivity remained low for all sites and for the overall diagnosis (54%). Conclusion The new radiographic definitions of CPPD are highly specific against the gold standard of histologic diagnosis. When the described radiographic findings are present, these definitions allow for a definitive diagnosis of CPPD, rather than other calcium‐containing crystal depositions; however, a negative radiographic finding does not exclude the diagnosis.

Domains

Health
Fichier principal
Vignette du fichier
Arthritis Rheumatology - 2022 - Sirotti - Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium.pdf (898.47 Ko) Télécharger le fichier
Origin Publisher files allowed on an open archive
Licence

Dates and versions

hal-04552308 , version 1 (19-04-2024)

Licence

Identifiers

Cite

Silvia Sirotti, Fabio Becce, Luca Sconfienza, Lene Terslev, Esperanza Naredo, et al.. Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group. Arthritis & rheumatology, 2023, 75 (4), pp.630-638. ⟨10.1002/art.42368⟩. ⟨hal-04552308⟩
9 View
8 Download

Altmetric

Share

More